D 2016

Analysis of the relationship of the system “operationally efficient building – indoor environment quality – user”

PAŠEK, Jan, Ingrid MATOUŠKOVÁ DRNCOVÁ, Petr ORT, Vojtěch CHLUBNA, Kateřina PAŠKOVÁ et. al.

Základní údaje

Originální název

Analysis of the relationship of the system “operationally efficient building – indoor environment quality – user”

Název česky

Analýza vztahu systému „provozně úsporná budova – kvalita vnitřního prostředí – uživatel“

Autoři

PAŠEK, Jan (203 Česká republika, garant, domácí), Ingrid MATOUŠKOVÁ DRNCOVÁ (203 Česká republika, domácí), Petr ORT (203 Česká republika, domácí), Vojtěch CHLUBNA (203 Česká republika, domácí), Kateřina PAŠKOVÁ (203 Česká republika, domácí), Martin CUPAL (203 Česká republika, domácí), Lenka KOLÁŘOVÁ (203 Česká republika, domácí), Diana TVRZNÍKOVÁ (203 Česká republika, domácí) a Jiří HORÁK (203 Česká republika, domácí)

Vydání

Switzerland, Applied Mechanics and Materials (Volume 824), od s. 199 - 209, 11 s. 2016

Nakladatel

Trans Tech Publications Inc.

Další údaje

Jazyk

angličtina

Typ výsledku

Stať ve sborníku

Obor

20101 Civil engineering

Stát vydavatele

Švýcarsko

Utajení

není předmětem státního či obchodního tajemství

Forma vydání

elektronická verze "online"

Kód RIV

RIV/02819180:_____/16:#0000053

Organizační jednotka

Výzkumné centrum BIVŠ, z.ú.

ISSN

Klíčová slova česky

Provozně úsporná stavba; energeticky úsporná stavba; vnitřní prostředí; facility management

Klíčová slova anglicky

Operationally efficient building; energy efficient building; indoor environment; facility management

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 6. 4. 2016 14:45, Dr. Jan Lachman

Anotace

V originále

The research focused on the analysis of the interaction of the individual components of the system operationally efficient building – indoor environment quality – user has been conducted since 2014 in the Czech Republic by a research team of Banking Institute / College of Banking. The purpose of the research is the evaluation of advantages and disadvantages of operationally efficient buildings by their owners, users or facility managers. One of the most monitored research parameters is the rating of indoor environment quality and its influence in physical and psychological fitness and work performance of the building users. Next, there are also other relationships which are examined – as the importance of the indoor environment quality with regards to other building's parameters, its influence on the real estate market value and the users' willingness to participate on the creation and keeping of indoor environment quality. The interpretation of gathered data proved a significant difference of the individual users' demands in relation to their individual preferences. This fact is necessary to respect while design and managing the operationally efficient buildings.

Česky

Výzkum zaměřený na analýzu interakce jednotlivých složek systému provozně úsporná budova – kvalita vnitřního prostředí – uživatel provádí v ČR od roku 2014 tým pracovníků Bankovního institutu vysoké školy. Účelem výzkumu je hodnocení výhod a nevýhod užívání provozně úsporných staveb jejich vlastníky, uživateli nebo správci. Jedním z nejsledovanějších parametrů výzkumu je hodnocení kvality vnitřního prostředí a jeho vliv na fyzickou i psychickou kondici a pracovní výkonnost uživatelů staveb. Vedle toho jsou zkoumány i další souvislosti, jako je význam kvality vnitřního prostředí vzhledem k dalším parametrům staveb, jeho vliv na hodnotu nemovitostí na realitním trhu a na ochotu uživatelů se na tvorbě a udržení kvality vnitřního prostředí podílet. Vyhodnocení dosud získaných dat prokázalo značnou rozdílnost nároků jednotlivých uživatelů v závislosti na jejich individuálních preferencích. Tuto skutečnost je třeba respektovat při návrhu a zejména správě provozně úsporných staveb.