a 2022

SELECTED SPECTROMETRIC METHODS FOR DETERMINATION OF IODINE IN BIOLOGICAL SAMPLES

FIŠERA, Miroslav; Pavel VALÁŠEK; Helena VELICHOVÁ and Lenka FIŠEROVÁ

Basic information

Original name

SELECTED SPECTROMETRIC METHODS FOR DETERMINATION OF IODINE IN BIOLOGICAL SAMPLES

Authors

FIŠERA, Miroslav (203 Czech Republic, guarantor, belonging to the institution); Pavel VALÁŠEK; Helena VELICHOVÁ and Lenka FIŠEROVÁ

Edition

European Symposium on Analytical Spectrometry, 2022

Other information

Language

English

Type of outcome

Conference abstract

Field of Study

10406 Analytical chemistry

Country of publisher

Czech Republic

Confidentiality degree

is not subject to a state or trade secret

References:

URL

Organization unit

AMBIS University

ISBN

978-80-88195-41-2

Keywords in English

iodine; biological samples; Analytical Spectrometry

Tags

RIV_VŠOH
Changed: 14/4/2023 13:20, Bc. Olga Puldová

Abstract

In the original language

This article compares different methods for determination of iodine in biological samples. Most frequently, indirect methods are applied in clinical practice. Sandell-Kolthoff spectrophotometric method of iodine determination [1] ranks among the most widely used ones; researchers also developed other modifications of the above method. Regarding direct determination, the following methods are considered the most suitable ones: emission spectrometry with inductively coupled plasma (ICP-OES), electrochemical methods, mass spectrometry with inductively coupled plasma (ICP-MS), and nuclear activation analysis (NAA) [2]. The ICP-MS and NAA are costly, but iodine can be analyzed directly regardless of its form, oxidation state, and isotopic distribution of iodine [3]. On the contrary, electrochemical, and ICP-OES determinations can be complicated with remarkable spectral interferences and also with dependence on possible presence of various forms and oxidation states of iodine in samples [4]. We compared three most frequently used methods for determination of iodine in selected biological materials: Sandell-Kolthoff spectrophotometric determination, ICP-OES and ICP-MS techniques [5]. The samples of biological materials such as foods and food supplements corresponding to content of iodine in urine were selected (Jooste and Strydom 2010). A NIST-SRM-1549 Milk powder certified reference material (CRM) with certified iodine concentration (3.38+0.6 mg/kg) was used to control the accuracy of the total iodine determination. The least accurate results were obtained by ICP-OES in analyses of given CRM (5.64+0.39 mg/kg), better results were acquired by spectrophotometric method (4.53+0.23 mg/kg) and the most accurate results were provided by ICP-MS method (3.36+0.12 mg/kg of iodine).
Displayed: 8/10/2025 13:55